Catalogue Pressure Transmitter

56 www.bdsensors.com DMP 335 Industrial Pressure Transmitter Technical Data Wiring diagrams 2-wire-system (current) 3-wire-system (voltage) Pin configuration Electrical connections ISO 4400 Binder 723 (5-pin) M12x1 (4-pin) field housing cable colours (DIN 47100) Supply + Supply – Signal + (only for 3-wire) 1 2 3 3 4 1 1 2 3 IN + IN – OUT + wh (white) bn (brown) gn (green) Shield ground pin 5 4 ye/gn (yellow / green) Electrical connections (dimensions in mm) standard option ISO 4400 Binder series 723 5-pin M12x1 4-pin cable outlet with PVC cable (IP 65) (IP 67) (IP 67) (IP67) 3 compact field housing cable outlet, (IP 67) cable with ventilation tube (IP 68) 4  universal field housing stainless steel 1.4404 (316 L) with cable gland M20x1.5 (ordering code 880) and other versions on request 3 standard: 2 m PVC cable without ventilation tube (permissible temperature: -5 ... 70 °C) 4 different cable types and lengths available, permissible temperature depends on kind of cable supply + signal + VS V p U supply – p supply + supply – VS I DMP 335 Technical Data