129 www.bdsensors.com HU 300 Hammer Union Pressure Transmitter Technical Data Miscellaneous Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 150 pF/m cable inductance: signal line/shield also signal line/signal line: 1 µH/m Current consumption 2-wire signal output current: max. 50 mA 3-wire signal output voltage: approx. 15 mA 4-wire signal output voltage: 29 mA @ 10 V Installation position any Weight 2.1 kg Wiring diagrams 2-wire 3-wire 4-wire Pin configuration Electrical connection MIL-/ Bendix (6-pin) Glenair (4-pin) cable colours (DIN 47100) Supply + Supply – Calibration + Calibration – for 3-wire / 4-wire: Signal + Signal – pin A pin B pin E pin F pin C pin D pin C pin B pin D pin A - - wh (white) bn (brown) pk (pink) gy (grey) - - Shield cable shield / for 2-wire: pin D plug housing ye/gn (yellow / green) Electrical connections (dimensions in mm) standard on request MIL-/ Bendix (6-pin) Glenair (4-pin) cable outlet PT02_E10-6P-023 GC379-2-14S-2P (IP 68) (IP 67) (IP 65) D E A F B CAL+ S+ CAL─ S─ p I VS A + ─ A B C D E F VS+ VS─ S+ S─ CAL+ CAL─ p I VS V + ─ A B C D E F VS+ VS─ S+ S─ CAL+ CAL─ p I VS V/A + ─ HU 300 Technical Data