15 LMK 382H Stainless Steel Probe Technical Data IS-protection Approval DX15A-LMK 382H IBExU 10 ATEX 1186 X zone 0 7 : II 1G Ex ia IIB T4 Ga zone 20: II 1D Ex ia IIIC T85 °C Da Safety technical maximum values Ui = 28 V, Ii = 93 mA, Pi = 660 mW, Ci = 13,2 nF, Li = 0 µH, the supply connections have an inner capacity of max. 27 nF opposite the enclosure Permissible media temperature in zone 0: -10 ... 60 °C with patm 0.8 bar up to 1.1 bar zone 1 or higher: -25 ... 70 °C Connecting cables (by factory) cable capacitance: signal line/shield also signal line/signal line: 160 pF/m cable inductance: signal line/shield also signal line/signal line: 1µH/m 7 for optional stainless steel pipe following designation is valid: "II 1G Ex ia IIC T4" (zone 0) Wiring diagram 2-wire-system (current) HART ® Pin configuration Electrical connection cable colours (IEC 60575) Supply + Supply – wh (white) bn (brown) Shield gnye (green-yellow) Dimensions (in mm) dimensions in mm dimen- sions DN25 / PN40 DN40/ PN40 DN50 / PN40 DN80 / PN16 D 115 150 165 200 K 85 110 125 160 d4 68 88 102 138 b 18 18 20 20 f 2 3 3 3 n 4 4 4 8 d2 14 18 18 18 HART ® is a registered trade mark of HART Communication Foundation; Windows ® is a registered trade mark of Microsoft Corporation flange versionthread R1" for stainless steel pipe standard p supply + supply – VS I LMK 382 H Technical Data www.bdsensors.com zone 07 D 115150165200 K 85110125160 d4 6888102138 b 18182020 f 2333 n 4448 d2 14181818