Catalogue Level EN_2016-01

109 www.bdsensors.com KL 2 Technical Data KL 2 Terminal Box Technical Data General specifications Number of signal lines 2-wire (4 ... 20 mA) Housing material plastic ABS, grey Ingress protection IP 66 Cable entries cable gland M16x1.5 Polyamide, seals NBR, IP 68, diameter range: standard 5 ... 10 mm others on request Atmospheric pressure compensation pressure balance item with PTFE filter Terminal clamps vertical clamps for stranded and solid wires up to 2.5 mm2 Weight approx. 220 g Optional overvoltage protection Series resistance 10 Ω for each wire Nominal discharge current 10 kA (8/20 µs) Max. rated current 30 mA Optional HART® connection Connections terminal clamp connection Wiring diagram Version with 2 channels, eg. LMK 307T, LMP 307T * The supply VS has to be chosen according to needs of the used transmitter. The ground wires of all components have to be connected! Dimensions (in mm) standard version with 2 channels Version for two independent 2 wire circuits and over voltage protection, eg. for LMK 307T, LMP 307T HART ® is a registered trade mark of HART Communication Foundation KL2_E_180814 ©2014BD|SENSORSGmbH–Thespecificationsgiveninthisdocumentrepresentthestateofengineeringatthetimeofpublishing.Wereservetherighttomakemodificationstothespecificationsandmaterials. depth of housing: 55 mm Mounting hole ∅ 4.2 equipped only with HART ® version Cable gland M16x1.5 Pressure balance item IN+ IN-GND HART  HA Cable gland M16x1.5 Pressure balance item supply – supply + Interface HART RS 232 C PC VS * This document contains product specifications; properties are not guaranteed. Subject to change without notice.