Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Catalogue Displays

22 www.bdsensors.com CIT 300 Process Display Technical Data pressure measurement CIT300_E_100712 Tel +49 (0) 92 35 / 98 11- 0 www.bdsensors.com Supply Supply voltage standard: 85 … 260 VAC or VDC option: 16 … 35 VAC / 19 … 50 VDC Power consumption max. 4.5 VA or W Signal input Input signal standard: 0/4 … 20 mA, 0/1 … 5 V, 0/2 … 10 V option: PT100 / PT500 / PT1000 Contacts (optional) Contact 2 or 4 SPST-relay Switching voltage max. 250 VAC Switching current max. 1 A (cos φ 1) Analogue output (optional) Output signal 0/4 … 20 mA (only possible in combination with 2 contacts) Permissible load max. 700 Ω Transducer supply DC 24 VDC + 5%, - 10%, max. 100 mA Communication / Performance Communication interface RS-485 (Modbus RTU) Transmission speed 1200 - 115200 bit/sec. Permissible temperatures Operating temperature 0 … 50 °C Storage temperature -10 … 70 °C Electrical protection Electrical safety EN 61010-1 EMC EN 61326 Miscellaneous Type of protection IP 65 (front foil) Display 4-digit LED display, red, 4 x 20 mm Range of indication - 999 … 9999 + decimal point / temperature range: -100 … 600 °C Accuracy (25 °C) ± 0.1 % FSO tolerance band (0 … 50 °C): max. 0.25 % FSO Housing dimensions 96 x 48 x 98 mm Housing panel Housing material NORYL-GFN2S E1 Mechanical connection (dimensions in mm) mounting hole dimensions dimensions of brackets and connectors Thisdatasheetcontainsproductspecification,propertiesarenotguaranteed.Subjecttochangewithautnotice. CIT 300 Technical Data This document contains product specifications; properties are not guaranteed. Subject to change without notice.

Pages