Please activate JavaScript!
Please install Adobe Flash Player, click here for download

Catalogue Differential Pressure

24 www.bdsensors.com DPS 200 Differential Pressure Transmitter Technical Data DPS200_E_300113 Miscellaneous Display (optional) LC-Display, visible range 32.5 x 22.5 mm; 5-digit 7-segment-main display, digit size 8 mm, 8-digit 14-segment-additional display, digit size 5 mm; 52-segment-bargraph Current consumption 2-wire: signal output current: max. 22 mA 3-wire: signal output current: max. 30 mA signal output voltage: 7.5 mA (20 mA short circuit) display: + 1 mA Ingress protection IP 54 Weight approx. 165 g Installation position vertical 1 1 The devices are calibrated in a vertical position with the pressure port down. If this position is changed on installation there can be slight deviations in the zero point. Mechanical connections (dimensions in mm) Standard Ø 6.6 x 11 (for flex. tubes Ø 6) Option Ø 4.4 x 10 (for flex. tubes Ø 4) Wiring diagram 2-wire-system (current) 3-wire-system (current / voltage) Pin configuration Electrical connections Terminals 2-wire-system Terminals 3-wire-system supply + supply – signal + (only for 3-wire) 2 / + 3 / - 1 (not connected) 2 / VS+ 3 / VS- 1 / SIG Dimensions (in mm) standard: DPS 200 without display optional: DPS 200 with display cable gland M12x1.5 Thisdatasheetcontainsproductspecification,propertiesarenotguaranteed.Subjecttochangewithoutnotice. cable gland M12x1.5 supply + signal + VS A/V p I/U supply – p supply + supply – VS I DPS 200 Technical Data