Please activate JavaScript!
Please install Adobe Flash Player, click here for download

product overview

8 x|act ci DMP 333 iDMP 331 i x|act i HART® HART® PRESSURE TRANSMITTER PRECISION stainless steel sensor laboratory, environmental industry nominal pressure 0 ... 400 mbar to 0 ... 40 bar (DMP 331i) 0 ... 60 bar to 0 ... 600 bar (DMP 333 i) accuracy 0.1% FSO (according to IEC 60770) characteristics digital electronics for linearisation and active temperature compensationn (temperature error 0.02% / 10 K), with communication interface for offset and span adjustment option IS-version, digital communication interface application stainless steel sensor hygienic applications nominal pressure 0 … 400 mbar to 0 … 40 bar (turn-down 1:10 adjustable) accuracy 0,1 % FSO (according to IEC 60770) process connection G1“ cone, clamp, dairy pipe, Varivent® , DRD, flange characteristics hygienic version, display and operating module cooling element up to 300 °C option IS-version application ceramic sensor hygienic applications nominal pressure 0 … 60 mbar to 0 … 20 bar (turn-down 1:10 adjustable) accuracy 0.2 % FSO (accoding to IEC 60770) process connection G1 ½“ flush, clamp, dairy pipe, Varivent® , flange, DRD characteristics hygienic version, display and operating module, diaphragm 99.9 % Al2 O3 option IS-version application hygienic design hygienic design