plant and machine engineering

Plant and mechanical engineering is a global industry involving complex applications. This demands flexibility, quality, reliability and customer focus. Given the wide range of possible applications, there is a need for various pressure ranges, appropriate accuracies, suitable electrical and mechanical connections and output signals agreed in consultation with the customer.              

products for plant and machine engineering of BD|SENSORS

Find quickly the appropriate pressure transmitter for your application! Select according to product range and/or sensor technology:

sensor / diaphragm: reset selection
OEM Pressure Transmitter Heavy Duty; welded stainless steel sensor; ISO 4400

17.600 G

stainless steel sensor, welded
mobile hydraulics
  • nominal pressure:0 ... 6 bar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE UL
OEM Pressure Transmitter for refrigeration; ISO 4400; mechanical connection 7/16"-20 UNF

17.609 G

stainless steel sensor, welded
refrigeration
  • nominal pressure:0 ... 6 bar up to 0 ... 60 bar / -1 ... 6 bar up to -1 ... 60 bar
  • accuracy:0.5 % FSO
  • certificates: CE UL
OEM Pressure Transmitter for Pneumatics; plug ISO 4400; G 1/4" connection

18.600 G

stainless steel sensor without media isolation
pneumatics
  • nominal pressure:0 ... 100 mbar up to 0 ... 6 bar
  • accuracy:0.5 % FSO
  • certificates: CE UL
OEM Pressure Transmitter for low pressure; general industrial applications; ISO 4400 plug; G 1/4" connection

18.601 G

stainless steel sensor
general industrial applications
  • nominal pressure:0 ... 100 mbar up to 0 ... 6 bar
  • accuracy:0.5 % FSO
  • certificates: CE UL
Submersible OEM-Pressure Transmitter with G 1/4" connection

18.605 G

stainless steel sensor
general industrial applications
  • nominal pressure:0 ... 1 mH2O up to 0 ... 10 mH2O
  • accuracy:0.5 % FSO
  • certificates: CE
OEM Pressure Transmitter Standard with plug ISO 4400 and G 1/4" connection

26.600 G

ceramic sensor
universal applications
  • nominal pressure:0 ... 1 bar up to 0 ... 400 bar
  • accuracy:0.5 % FSO
  • certificates: CE UL
OEM Pressure Transmitter Low Cost with plug ISO 4400 and G 1/4" connection

30.600 G

ceramic sensor
universal applications
  • nominal pressure:0 ... 1,6 bar up to 0 ... 250 bar
  • accuracy:1 % FSO
  • certificates: CE UL

BAROLI 02

stainless steel sensor
laboratory, environmental industry
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0.125 % FSO BFSL (class 0.1)
  • certificates: CE

BAROLI 05

ceramic sensor
laboratory, environmental industry
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.25 % FSO BFSL (class 0.2)
  • certificates: CE

DAC 102


dynamic pressure measurements<br /> for precision measurement
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar35
  • natural frequency kHz85

DAC 103


dynamic pressure measurements<br /> for heavily vibrating systems
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar16
  • natural frequency kHz165
Piezoelectric pressure sensor DAC 105

DAC 105


dynamic pressure measurements for high<br /> pressure at moderate temperatures
  • nominal pressure range0 ... 500 bar
  • operating temperature °C-50 ... 120
  • sensitivity pC/bar19
  • natural frequency kHz170
Piezoelectric pressure sensor DAC 105G

DAC 105G


dynamic pressure measurements<br /> all-round sensor
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar19
  • natural frequency kHz160
Piezoelectric pressure sensor DAC 105K

DAC 105K


dynamic pressure measurements<br /> all-round sensor
  • nominal pressure range0 ... 300 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar19
  • natural frequency kHz170
Piezoelectric pressure sensor DAC 106G

DAC 106G


dynamic pressure measurements<br /> all-round sensor
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar19
  • natural frequency kHz160
Piezoelectric pressure sensor DAC 106K

DAC 106K


dynamic pressure measurements<br /> all-round sensor
  • nominal pressure range0 ... 300 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar19
  • natural frequency kHz170
Piezoelectric pressure sensor DAC 106L

DAC 106L


dynamic pressure measurements<br /> for high pressures at high temperatures
  • nominal pressure range0 ... 500 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar10
  • natural frequency kHzapprox. 170
Piezoelectric pressure sensor DAC 106U

DAC 106U


dynamic pressure measurements<br /> Extremely rapid, for high pressures
  • nominal pressure range0 ... 650 bar
  • operating temperature °C-40 … 350
  • sensitivity pC/barapprox. 1.5
  • natural frequency kHz> 400

DAC 107


dynamic pressure measurements<br /> for precision measurement
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 ... 400
  • sensitivity pC/bar45
  • natural frequency kHzapprox. 92

DAC 109


dynamic pressure measurements<br /> highly robust, continual use
  • nominal pressure range0 ... 250 bar
  • operating temperature °C-40 … 350
  • sensitivity pC/bar20
  • natural frequency kHzapprox. 90

DAC 120


dynamic pressure measurements<br /> for extreme pressure peaks
  • nominal pressure range0 ... 2000 bar
  • operating temperature °C-50 … 200
  • sensitivity pC/bar5.2
  • natural frequency kHz> 240

DAC 160


dynamic pressure measurements<br /> for extreme pressure peaks
  • nominal pressure range0 ... 6000 bar
  • operating temperature °C-50 … 200
  • sensitivity pC/bar3
  • natural frequency kHz> 240

DAC 180


dynamic pressure measurements<br /> for extreme pressure peaks
  • nominal pressure range0 ... 8000 bar
  • operating temperature °C-50 … 200
  • sensitivity pC/bar2.3
  • natural frequency kHz> 240

DCT 531

stainless steel sensor
with RS485 Modbus RTU
  • nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
  • accuracy:0,35 % FSO
  • certificates: CE

DCT 532

stainless steel sensor
with i²C interface
  • nominal pressure:0 ... 100 mbar bis 0 ... 400 bar
  • accuracy:0,35 % FSO
  • certificates: CE

DCT 533

stainless steel sensor
with IO-Link interface
  • nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
  • accuracy:0,35 % FSO
  • certificates: CE IO-Link
Battery Powered Precision Digital Gauge for Leak Testing

DL 01

stainless steel sensor
Leak testing, Pipeline monitoring
  • nominal pressure:0 …100 mbar up to 0 ... 400 bar
  • certificates: CE

DM 01

stainless steel sensor
test and calibration equipment
  • nominal pressure:0 ... 100 mbar up to 0 ... 400 bar
  • accuracy:0.05 % FSO BFSL (class 0.05)
  • certificates: CE Ex UL

DM 10

ceramic sensor
plant and mechanical engineering
  • nominal pressure:0 ... 1,6 bar up to 0 ... 250 bar
  • accuracy:0.5 % FSO BFSL (class 0.5)
  • certificates: CE UL

DM 17

stainless steel sensor
Plant and Machine Engineering
  • nominal pressure:0 ... 6 bar up to 0 ... 600 bar
  • accuracy:0,5 % FSO BFSL (class 0,5)
  • certificates: CE UL

DMD 331

stainless steel sensor
plant and mechanical engineering
  • differential pressure0 ... 20 mbar up to 0 ... 16 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex

DMD 341

silicon sensor
plant and mechanical engineering
  • differential pressure0 ... 6 mbar up to 0 ... 1000 mbar
  • accuracy:0.35 % / 1% / 2% FSO
  • certificates: CE

DMD 831

stainless steel sensor
plant and mechanical engineering
  • differential pressure0 ... 1 bar up to 0 ... 70 bar
  • accuracy:1 % FSO
  • certificates: CE
Industrial Pressure Transmitter with Ceramic Sensor; oxygen application; pressure port G 1/2"

DMK 331

ceramic sensor
universal applications
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex IECEX SIL UL
Industrial Pressure Transmitter; suited for viscous and pasty media; plug ISO 4400

DMK 331 P

stainless steel diaphragm, flush
hygienical application
  • nominal pressure:0 ... 60 bar up to 0 ... 400 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex IECEX SIL UL
Pressure Transmitter with Ceramic Sensor; capacitive sensor; high media resistance

DMK 351

ceramic sensor
laboratory techniques, biogas plants
  • nominal pressure:0 ... 40 mbar up to 0 ... 20 bar
  • accuracy:0,25 % / 0.35 % FSO
  • certificates: CE Ex UL
Pressure Transmitter for Porcess Industry; hygenical version; process connections G 1/2", diary pipe, clamp etc.

DMK 351 P

ceramic sensor, flush
hygienical application
  • nominal pressure:0 ... 40 mbar up to 0 ... 20 bar
  • accuracy:0.25 % / 0.35 % FSO
  • certificates: CE Ex UL
Pressure Transmitter for Shipbuilding and Offshore; pressure port CuNiFe; shipping approvals LR, GL, DNV and CCS

DMK 457

ceramic sensor
marine, shipbbuilding, offshore
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex IECEX Lloyd´s Register GL DNV CCS
Pressure Transmitter for Marine and Offshore; diaphragm AI2O3 99.9%; shipping approvals

DMK 458

ceramic sensor
marine, shipbbuilding, offshore
  • nominal pressure:0 ... 40 mbar up to 0 ... 20 bar
  • accuracy:0.25 % FSO
  • certificates: CE Ex Lloyd´s Register GL DNV CCS
Industrial Pressure Transmitter for ultra high pressure; front sided potentiometers; pressure port 9/16" UNF

DMP 304

stainless steel sensor strain gauge
oil and gas industry
  • nominal pressure:0 ... 2000 bar up to 0 ... 6000 bar
  • accuracy:0,25 % / 0.5 % FSO
  • certificates: CE Ex
Precision Pressure Transmitter with Fast Response Time

DMP 320

stainless steel sensor
with fast response time
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0,1 % FSO
  • certificates: CE
Industrial Pressure Transmitter

DMP 321

stainless steel sensor
universal application
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0,1 % / 0,25 % FSO
  • certificates: CE Ex IECEX UL
Industrial Pressure Transmitter for Low Pressure with Stainless Steel Sensor;

DMP 331

stainless steel sensor
universal applications
  • nominal pressure:0 ... 100 mbar up to 0 ... 60 bar
  • accuracy:0,1 / 0,25 / 0,35 %
  • certificates: CE Ex IECEX SIL UL
Industrial Pressure Transmitter for High Pressure; long-term stability; insensitive to pressure peaks; high overpressure capability

DMP 333

stainless steel sensor
universal applications
  • nominal pressure:0 ... 100 bar up to 0 ... 600 bar
  • accuracy:0,1 % / 0,25 % / 0.35 % FSO
  • certificates: CE SIL Ex IECEX UL
Industrial Pressure Transmitter for High Pressure; Thinfilm Sensor; long-term stability; pressure sensor welded

DMP 334

stainless steel sensor, welded
plant and mechanical engineering
  • nominal pressure:0 ... 600 bar up to 0 ... 2.200 bar
  • accuracy:0.35 % FSO
  • certificates: CE Ex IECEX UL

DMP 334i

stainless steel sensor, welded
Plant and Machine Engineering
  • nominal pressure:0 ... 600 up to 0 ... 2.200 bar
  • accuracy:0,1 % FSO
  • certificates: CE
Industrial Pressure Transmitter; welded, dry Stainless Steel Sensor; suitable for oxygen applications

DMP 335

stainless steel sensor, welded
medical technology, hydraulics
  • nominal pressure:0 ... 6 bar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex IECEX UL
Industrial Pressure Transmitter with G 1/4" flush pressure port; suitable for viscous and pasty media

DMP 339

stainless steel sensor
flush version G 1/4"
  • nominal pressure:0 ... 60 bar up to 0 ... 600 bar
  • accuracy:0,35 % FSO
  • certificates: CE Ex IECEX UL
pressure transmitter for very low pressure with ISO 440 connector and G 1/4" pressure port

DMP 343

stainless steel sensor without media isolation
HVAC
  • nominal pressure:0 ... 10 mbar up to 0 ... 1000 mbar
  • accuracy:0.35 %
  • certificates: CE Ex IECEX UL
Pressure Transmitter for Shipbuilding and Offshore; flush pressure port G 1/2" from 100 mbar; excellent thermal characteristic

DMP 457

stainless steel sensor
marine, shipbbuilding, offshore
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0.25 % / 0.35 % FSO
  • certificates: CE Ex IECEX Lloyd´s Register GL DNV CCS
precision pressure transmitter with M12x1 connector and G1/2" pressure port

DMP i

stainless steel sensor
laboratory, environmental industry
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.1 % FSO
  • certificates: CE Ex IECEX

DPS 200

silicon sensor
HVAC
  • differential pressure0 ... 6 mbar up to 0 ... 1.000 mbar
  • accuracy:1 % FSO
  • certificates: CE

DPT 100

stainless steel sensor
test engineering, machine and plant engineering
  • differential pressurefrom10 mbar up to 20 bar
  • accuracy:0,1 % FSO
  • certificates: CE

DPT 200

stainless steel sensor
process, oil and gas industry
  • differential pressurevon 1 mbar bis 20 bar
  • accuracy:0,075 % FSO
  • certificates: CE Ex IECEX HART

XMD

stainless steel sensor
process, oil and gas industry
  • nominal pressure:0 ... 75 mbar up to 0 ... 20 bar
  • accuracy:0.1 % FSO
  • certificates: CE Ex HART
Process Pressure Transmitter with HART-communication

XMP ci

ceramic sensor
process, oil and gas industry
  • nominal pressure:0 ... 160 mbar up to 0 ... 20 bar
  • accuracy:0,1 % FSO
  • certificates: CE HART Ex
Precision Pressure Transmitter for the Process Industry with HART-Communication and Stainless Steel Sensor

XMP i

stainless steel sensor
process, oil and gas industry
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0,1 % FSO
  • certificates: CE HART Ex 3A

LMK 331

ceramic sensor, flush
plant and mechanical engineering
  • nominal pressure:0 ... 400 mbar up to 0 ... 60 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex IECEX SIL UL

LMK 351

ceramic sensor, flush
environmental industry, renewable energy
  • nominal pressure:0 ... 40 mbar up to 0 ... 20 bar
  • accuracy:0.25 % / 0.35 % FSO
  • certificates: CE Ex UL

LMP 331

stainless steel sensor
plant and mechanical engineering
  • nominal pressure:0 ... 100 mbar up to 0 ... 40 bar
  • accuracy:0,1 % / 0,25 % / 0.35 % FSO
  • certificates: CE Ex IECEX SIL UL

DS 200

stainless steel sensor
universal applications
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0.25 % / 0.35 % FSO
  • certificates: CE Ex

DS 201

ceramic sensor
universal applications
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex

DS 201 P

stainless steel diaphragm, flush
hygienical application
  • nominal pressure:0 ... 60 bar up to 0 ... 400 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex

DS 202

stainless steel sensor, welded
medical technology, oxigen application
  • nominal pressure:0 ... 6 bar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex

DS 210

stainless steel sensor without media isolation
HVAC
  • nominal pressure:0 ... 10 mbar up to 0 ... 1 bar and vacuum -1 ... 0 bar
  • accuracy:0.25 % / 0,35 % FSO
  • certificates: CE Ex

DS 214

stainless steel sensor, welded
Plant and Machine Engineering
  • nominal pressure:0 ... 600 bar up to 0 ... 2200 bar
  • accuracy:0,35 % FSO
  • certificates: CE

DS 217

stainless steel sensor, welded
hydraulics, oxygen applications
  • nominal pressure:0 ... 6 bar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE

DS 230

ceramic sensor
pneumatics, hydraulics
  • nominal pressure:0 ... 2 bar up to 0 ... 400 bar
  • accuracy:1.5 % FSO
  • certificates: CE

DS 233

silicon sensor
Heating and Air Conditioning
  • nominal pressure:0 ... 6 mbar up to 0 ... 1000 mbar
  • accuracy:0,35 % FSO
  • certificates: CE
Electronic Pressure Switch

DS 300

stainless steel sensor
with IO-Link interface
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0,35 % FSO
  • certificates: CE IO-Link UL

DS 4

silicon sensor
pneumatics
  • nominal pressure:0 ... 1 bar up to 0 ... 10 bar, -1 bar ... 0 bar
  • accuracy:1 % FSO
  • certificates: CE

DS 400

stainless steel sensor
Hygienic Design
  • nominal pressure:0 ... 100 mbar up to 0 ... 600 bar
  • accuracy:0.25 % / 0.35 % FSO
  • certificates: CE Ex

DS 401

ceramic sensor
universal applications
  • nominal pressure:0 ... 400 mbar up to 0 ... 600 bar
  • accuracy:0.5 % FSO
  • certificates: CE Ex

DS 6

ceramic sensor
hydraulics
  • nominal pressure:0 ... 2 bar up to 0 ... 400 bar
  • accuracy:1 % FSO
  • certificates: CE